05/22/2018
2:59 AM
City of Irving - Inspection Report  
Permit No. E1801-0082 Permit Type   ELECTRICAL Site Address   4108 SAGUARO LN
IRVING, TX 75063
Applied   01/15/2018 Applicant   EDWARD BAYLOR
Approved   01/19/2018 Owner   DARLING HOMES OF TEXAS LLC
Issued   01/19/2018 Contractor   IN CHARGE ELECTRICAL SERVICES
Parent Permit No.   B1801-0114 Description   NEW SFD
  Notes  
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

 02/01/2018TEMPORARY POLEJustin KriegDISAPPROVED/FAILeTRAKiT Inspection Request2/1/2018 5:57 AM IN CHARGE ELECTRICAL SERVICES Contact Name: IN CHARGE ELECTRICAL SERVICES Site Address: 4108 SAGUARO LN Phone: 9722921478 e-Mail: joegomez@in-charge-electric.com (2/1/2018 2:49 PM JKK) Not Installed

 02/05/2018TEMPORARY POLEJustin KriegDISAPPROVED/FAILeTRAKiT Inspection Request2/2/2018 6:00 AM IN CHARGE ELECTRICAL SERVICES Contact Name: IN CHARGE ELECTRICAL SERVICES Site Address: 4108 SAGUARO LN Phone: 9722921478 e-Mail: joegomez@in-charge-electric.com (2/5/2018 4:04 PM JKK) Close all openings in panel by listed means in order to retain 3R rating

 02/09/2018TEMPORARY POLEJustin KriegAPPROVED/PASSeTRAKiT Inspection Request2/9/2018 5:44 AM IN CHARGE ELECTRICAL SERVICES Contact Name: IN CHARGE ELECTRICAL SERVICES Site Address: 4108 SAGUARO LN Phone: 9722921478 e-Mail: joegomez@in-charge-electric.com

 04/27/2018ELECTRICAL ROUGHJustin KriegDISAPPROVED/FAILeTRAKiT Inspection Request4/26/2018 4:05 PM IN CHARGE ELECTRICAL SERVICES Contact Name: IN CHARGE ELECTRICAL SERVICES Site Address: 4108 SAGUARO LN Phone: 9722921478 e-Mail: joegomez@in-charge-electric.com (4/27/2018 3:56 PM JKK) Cables bundled in garage attic (create separation) Cables wrapped around beam (create separation) Cables within 1 1/2" of roof decking (create at least 1 1/2" of separation from decking) General wall recept ; kitchen nook Vent fan circuits not installed Low volt panel: Framing member out of sorts Circuit not installed Cable outside of framing member ; upstairs hallway

 05/02/2018ELECTRICAL ROUGHJustin KriegDISAPPROVED/FAILeTRAKiT Inspection Request5/1/2018 9:03 AM IN CHARGE ELECTRICAL SERVICES Contact Name: IN CHARGE ELECTRICAL SERVICES Site Address: 4108 SAGUARO LN Phone: 9722921478 e-Mail: joegomez@in-charge-electric.com (5/2/2018 3:46 PM JKK) No change: Cables bundled in garage attic (create separation) Cables wrapped around beam (create separation) Cables within 1 1/2" of roof decking (create at least 1 1/2" of separation from decking) Other work in progress during inspection

 05/07/2018ELECTRICAL ROUGHJustin KriegDISAPPROVED/FAILeTRAKiT Inspection Request5/7/2018 5:59 AM IN CHARGE ELECTRICAL SERVICES Contact Name: IN CHARGE ELECTRICAL SERVICES Site Address: 4108 SAGUARO LN Phone: 9722921478 e-Mail: joegomez@in-charge-electric.com (5/7/2018 3:13 PM JKK) No change: Cables bundled in garage attic (create separation) Cables wrapped around beam (create separation) Cables within 1 1/2" of roof decking (create at least 1 1/2" of separation from decking)

 05/09/2018ELECTRICAL ROUGHJustin KriegDISAPPROVED/FAILeTRAKiT Inspection Request5/8/2018 3:51 PM IN CHARGE ELECTRICAL SERVICES Contact Name: IN CHARGE ELECTRICAL SERVICES Site Address: 4108 SAGUARO LN Phone: 9722921478 e-Mail: joegomez@in-charge-electric.com (5/9/2018 3:04 PM JKK) No Change

 05/18/2018ELECTRICAL ROUGHJustin KriegDISAPPROVED/FAILeTRAKiT Inspection Request5/17/2018 5:31 PM IN CHARGE ELECTRICAL SERVICES Contact Name: IN CHARGE ELECTRICAL SERVICES Site Address: 4108 SAGUARO LN Phone: 9722921478 e-Mail: joegomez@in-charge-electric.com (5/18/2018 5:33 PM JKK) Furr-out frame is not yet built; need protection for conductors

 02/09/2018ELEC SVC RELEASEJustin KriegAPPROVED/PASS297 4629#tpole

 03/20/2018ELEC SLAB ROUGHHerb GillilandAPPROVED/PASS